CxLetterScan printer settings (print module)

Here you will find all available settings for the print module of the CxLetterScan (#CxLetterScanPrint)

Basic settings

A list with all available attributes for editing is displayed. The first column contains the name of the attribute, the second column contains the value of the attribute which can be edited. To edit a value, click with the mouse on the corresponding column and change the value.

General settings

Designation Default value Description
100: Timeout Print: Maximum permissible processing time for the preparation of the print image in ms 100 Maximum time in milliseconds that may be used to print a transmission. If the time exceeds this, an error is triggered and the machine is stopped.
200: Basic print offset in mm 95 Defines the default print offset that is applied to the printer module. This is the distance between the sensor on the print module and the 1st printhead. Nothing should be printed in this area until the letter has effectively reached the printhead (#CxLetterScanPrintOffset).
201: Automatic print offset in X-direction (longitudinal/running direction) No Defines whether the selected print layout is shifted in X-direction (longitudinal/running direction) to the best free area (white spot) (#CxLetterScanPrintVerzatz).
See Automatic Print Offset.
202: Automatic print offset in Y-direction (cross) No Defines whether the selected print layout is shifted in Y-direction (landscape) into the best free area (white spot) (#CxLetterScanPrintVerzatz).
See Automatic Print Offset.
210: Distance between printhead and guide bar [mm] 10.0 Defines the mechanical distance from the paper guide rail to the printhead.
220: Deviation factor of letter length in percent 20 This factor defines the number of percent of the measured letter length that the letter on the printer is allowed to deviate from. If the length is exceeded or fallen short of, the machine is stopped with the corresponding error.
Example with a factor of 10:
The measured letter on the camara module is 228 mm long, that means it must not be smaller than 205 mm and not longer than 250 mm on the printer module. The length changes if the letter is either placed at an angle after the print module or if 2 letters are pushed on top of each other.
400: Cartridge level: Warning limit in percent, default value is 10%. 10 This parameter can be used to set when a warning is displayed in the display of the CxLetterscan dialog in the print module under Printer status if the fill quantity defined here is not reached.

Automatic print offset

The automatic print offset (#CxLetterScanPrintVerzatz) offsets the print image so that it is printed in the best possible free area.
For this the image of the letter is analyzed and all free areas (white spots) are searched.
The position and size of the canvas defined in the print layoutis used to select the best free area.
The print image is shifted in X- and Y-direction according to the free area.

Standard error layouts for use cases

This grid shows all use cases that have the print function. For each use case, select a layout that will be printed on the letter in case of an error.

Printer layouts

This list shows all available printer layouts. These are managed here (edit, add, delete).

Faulty printer layouts (syntax errors, missing/empty elements/attributes, etc) are displayed with a red background.

A printer layout defines which data is printed in which format on an item. Various elements such as static text, variables, barcodes and images are supported. In order to position these elements, to define their font, etc., settings are required. This definition of the print layout is done in XML files (seePrintLayout Syntax).

Operation

  • Refresh
    The list with all available printer layouts is reloaded and displayed.

  • Edit
    The selected print layout is opened for editing in the dialog Printer Layout Details

  • Add
    A new print layout is added, for this the dialog Printer Layout Details is opened.

  • Delete
    The printer layout currently selected in the list is deleted. Confirmation is requested before deletion.

Pressure variables

The "Capture" use case supports the following print variables:

Pressure variable Category Content
UPOC Broadcast UPOC of the shipment
OrderIdentifier Broadcast Order identifier
AlternativeCode1 Broadcast Alternate code
AlternativeCode2 Broadcast Additional alternative code
AcquisitionTime Broadcast Acquisition time in local "Short time" format
AcquisitionDate Broadcast Entry date in local "short date" format
DeliveryDate Broadcast Planned delivery date/time in the format "Short date" + " " + "Short time".
OrderDate Broadcast Order date/time in the format "Short date" + " " + "Short time".
Name Receiver Use-Case "Capture-IHS":
a
) Recipient = person: first name + last name + name suffix
b) Recipient = LU: Name of LU
c) Recipient = KKS: Customer name1 + Customer name2 + Customer name3 + "/" + KsName1 + KsName2 + KsName3

Use-Case "Capture-AZD":
Complete recipient name in one line
PersonName1 Receiver Only IHS and recipient is person: Person.Name1 (first name)
PersonName2 Receiver Only IHS and recipient is person: Person.Name2 (last name)
PersonName3 Receiver Only IHS and recipient is person: Person.Name3 (name suffix)
Country Receiver Recipient country
Zip Receiver Recipient Postcode
City Receiver Recipient City WITH City District
CitySimple Receiver Recipient city WITHOUT district
Locality Receiver Recipient District
Street Receiver Recipient street WITH house number and WITH house number suffix
StreetSimple Receiver Recipient street WITHOUT house number
HouseNo Receiver Recipient House number incl. addition
SIX Sort info SortInfo SIX
SIDistrictStruct Sort info SortInfo district structure
SIDistrictGroup Sort info SortInfo District Group
SIDistrict Sort info SortInfo district
SIDepot Sort info SortInfo Depot
SIShipTour Sort info SortInfo delivery tour
SICity Sort info SortInfo Location
SIStreet Sort info SortInfo Street
SIHouseNoRange Sort info SortInfo House number range
SIDistrictIHS Sort info SortInfo District IHS
SILogisticUnit Sort info SortInfo Logistics unit
ZIAreaStreet Delivery info Delivery info street (area)
ZIDistrictStreet Delivery info Delivery info street (district)
ZIAreaHouse Delivery info Delivery info house (area)
ZIDistrictHouse Delivery info Delivery info house (district)
ZIPerson Delivery info Delivery info person
ServiceShortName Designation Short description of the service
DistrictName Designation District Name/Designation
DistrictGroupName Designation District Group Name/Designation
ServiceProviderName Designation Service Provider Name/Designation
ServiceProviderZoneName Designation Service Provider Zone Name/Designation
DepotName Designation Depot Name/Designation
ShipTourName Designation Delivery tour Name/designation
LogisticUnitName Designation Name of the logistics unit (only for IHS)
CostUnitNameFull Cost unit Full name (customer & cost center) of thecost unit assigned to the shipment.
Name1 + Name2 + Name3 of the customer + "/" + Name1 + Name2 + Name3 of the cost center.
ATTENTION: The cost unit depends on the setting in the use case (for IHS this can be the fixed cost unit or the cost unit of the recipient).
CostUnitName Cost unit Full name of the cost object assigned to the shipment.
a) Cost unit is customer: Name1 + Name2 + Name3 of the customer.
b) Cost object is cost center: Name1 + Name2 + Name3 of the cost center.
ATTENTION: The cost object depends on the setting in the use case (for IHS this can be the fixed cost object or the cost object of the recipient).
CostUnitName1 Cost unit Name1 of the cost unit assigned to the shipment.
a) Cost unit is customer: Name1 of the customer
b) Cost object is cost center: Name1 of the cost center
ATTENTION: The cost object depends on the setting in the use case (for IHS this can be the fixed cost object or the cost object of the recipient).
CostUnitCustomerName Cost unit Whole name (Name1 + Name2 + Name3) of thecustomer assigned to the shipment.
ATTENTION: The cost unit depends on the setting in the use case (for IHS this can be the fixed cost unit or the cost unit of the recipient).
CostUnitCustomerName1 Cost unit Name1 of the customer assigned to the shipment.
ATTENTION: The cost unit depends on the setting in the use case (for IHS this can be the fixed cost unit or the cost unit of the recipient).
CostUnitCostcenterName Cost unit Whole name (Name1 + Name2 + Name3) of the cost center assigned to the shipment.
ATTENTION: The cost unit depends on the setting in the use case (for IHS this can be the fixed cost unit or the cost unit of the recipient).
CostUnitCostcenterName1 Cost unit Name1 of the cost center assigned to the shipment.
ATTENTION: The cost unit depends on the setting in the use case (for IHS this can be the fixed cost unit or the cost unit of the recipient).
DeputyLabel Divers Text when transmission is diverted to the deputy
LevelNo Divers Level number
PostalCharges Divers Postage, postal charge
PrintSequenceTotal Broadcast A sequential number for items that are printed, this is reset when CodX PostOffice is started (#CxLetterScanSequenceNumber)
PrintSequenceRun Broadcast A sequential number for items being printed, this is reset when the machine is started (#CxLetterScanSequenceNumber).

See also:



CodX Software CodX Software AGbr /> Sinserstrasse 47
6330 Cham
Switzerland
Support
h ttp://support.codx.ch
CxSpickel